Benchtop 12 positions biochemical oxygen demand (BOD) meter LH-BO1201
According to the national standard (HJ 505-2009) Water quality-Determination of biochemical oxygen demand after five days (BOD5) for dilution and seeding method, 12 samples once, safe and reliable mercury-free differential pressure sensing method (breathing method) is used to measure BOD in water, which completely simulates the biodegradation process of organic matter in nature. R&D process design and manufacturing, industry-leading function settings, fully intelligent design, unattended measurement process, automatic recording of data, completely saying goodbye to mercury poisoning caused by mercury leakage, is a BOD specially tailored for water quality analysis laboratories Professional analytical instruments.
- Overview
- Features
- Specification
- Inquiry
- Related Products
Product introduction
According to the national standard (HJ 505-2009) Water quality-Determination of biochemical oxygen demand after five days(BOD5) for dilution and seeding method, 12 samples once, safe and reliable mercury-free differential pressure sensing method (manometric method) is used to measure BOD in water, which completely simulates the biodegradation process of organic matter in nature. R&D process design and manufacturing, industry-leading function settings, fully intelligent design, unattended measurement process, automatic recording of data, completely saying goodbye to mercury poisoning caused by mercury leakage, is a BOD specially tailored for water quality analysis laboratories Professional analytical instruments.
Features
1. Safe and reliable method: The mercury-free pressure difference method is adopted, which ensures no mercury pollution and accurate and reliable data.
2. Independent and flexible testing: Test individuals independently, and decide the start time of individual samples at any time.
3. Control system: A microprocessor control system is adopted to automatically complete the measurement process, eliminating the need for dedicated personnel supervision.
4. Wide measurement range and optional: It can measure BOD values ranging from (0-4000) mg/L without dilution.
5. Direct concentration reading: It can measure 1-12 samples without conversion, directly displaying the BOD concentration value.
6. Enhanced instrument mobility: Each testing cap has a built-in battery, so a brief power outage has no impact on testing, reducing dependence on electricity.
7. Easy to operate: Simply press the buttons to complete the settings, then bottle the water sample according to the volume set by the range, and the test is done.
8. Large batch processing capacity: Up to 12 samples can be tested at a time.
9. Automatic data recording: Current experimental data and five-day historical data of biochemical oxygen demand can be viewed at any time.
10. Complete experimental accessories: Equipped with all the reagents and accessories required for the experiment, facilitating accurate and rapid sampling.
Specification
Product Name |
Biochemical oxygen demand (BOD5 meter) |
Model |
LH-BOD1201 |
Accuracy |
≤±5% |
Range |
(0~4000)mg/L |
Minimum value |
2mg/L |
Volume |
580mL |
Repeatability |
≤±5% |
Samples |
12 samples once |
Data storage |
100 for one sensor |
Period |
1-30 days |
Dimension |
(390×294×95)mm |
Weight |
6.5Kg |
Test temperature |
(20±1)℃ |
Environment humidity |
≤85%RH (no condensation) |
Supply |
AC(100-240V)±10%/(50-60)Hz |
Power |
60W |
Have something in mind? Let's talk.