Biochemical Oxygen Demand (BOD5) apparatus LH-BOD306
Instrument Introduction
This instrument is a brand new instrument for measuring BOD in water based on manometric method. It can independently detect bottle caps and simulate the reaction process of the standard HJ505-2009. It is manufactured according to the international standard ISO9408-1999 and is particularly suitable for detecting water quality BOD indicators, selecting water treatment processes, and simulating water treatment processes. Support 1-30 day’s result.
- Overview
- Specifications
- Inquiry
- Related Products
Functional Features
1) Compliant with the national standard HJ505-2009 reaction process, manufactured based on ISO9408-1999, using a mercury free differential pressure method, with no mercury pollution and accurate and reliable data;
2) Each test cap enables independent configuration of sample‑related parameters. A maximum of 100 historical datasets can be stored per cap, with older records automatically overwritten once storage capacity is reached;
3) It supports testing for 1 to 6 samples. Equipped with a microprocessor‑driven control system, the unit completes the full measurement cycle automatically without on‑site operator attendance, and features independent timing for each channel;
4) The measuring range spans 0‑4000 mg/L with eight selectable range options. BOD values are displayed directly without manual conversion. Hardware upgrades deliver enhanced accuracy especially for low‑range measurements;
5) Powered by a CR‑P2 battery and fitted with a 1.5‑inch OLED screen, each test cap can operate standalone. Operators can access test results and data curve graphs directly. Brief power interruptions of the main base will not interfere with ongoing tests;
6) The main base integrates a six‑position electromagnetic stirring function, ensuring thorough sample homogenization throughout experiments for more reliable test outcomes;
7) Seven built‑in indicator lights offer visual status feedback for power supply and electromagnetic stirring operations;
8)Flexible time configuration is available: the test duration can be set from 1 to 30 days, and the constant‑temperature waiting period ranges from 1 to 10 hours;
Technical Parameter
|
Product name |
Biochemical Oxygen Demand (BOD5) Meter |
||
|
Model |
LH-BOD306 |
||
|
Standard basis |
Complies with the reaction process of the national standard HJ505-2009 and is manufactured based on ISO9408-1999 |
||
|
Display resolution |
0.1mg/L<10mg/L;1mg/L≥10mg/L |
||
|
Measurement range |
(0-4000)mg/L |
||
|
Accuracy of pressure measurement |
±2.5% |
Result recording frequency |
1 hour |
|
Measurement accuracy |
±10% |
Air tightness |
<0.1kpa/15min |
|
Measurement cycle |
1-30 days |
Measured data |
6 |
|
Bottle capacity |
580mL |
Store data |
100 |
|
Cultivation temperature |
20±1℃ |
Rated power |
30W |
|
Power configuration |
(100-240)V/(50-60)Hz |
Instrument weight |
2.6kg |
|
Ambient temperature |
(5-40)℃ |
Ambient humidity |
≤85RH(No condensation) |
|
Instrument size |
Stirrer:(280×206×97.5)mm;Full set: (280×206×324)mm |
||