Instrument Introduction

The LH‑E4ISE is a lab‑grade ion analyser capable of measuring pH, ORP and a variety of ion‑related parameters. Fitted with a 7‑inch touch screen and powered by the in‑house developed LHOS smart interactive system, it delivers highly intuitive operation. Characterised by stable performance, high‑precision measurement and extensive measuring ranges, this fully‑featured multi‑parameter device simplifies workflows and supports fast on‑site laboratory testing for end‑users.

Functional Feature

1. Developed around Lianhua’s proprietary LHOS platform, this electrochemical‑spark‑series laboratory multi‑parameter ion meter accepts BNC‑connector electrodes, delivering excellent cross‑compatibility.
2. A 7.0‑inch touch‑operated LCD screen offers straightforward programming, crystal‑clear visual feedback and hassle‑free operation.
3. One‑tap toggle between Chinese and English display modes; the dual‑language layout enhances usability for diverse users.
4. It satisfies the 0.01‑grade calibration criteria specified in national metrological standard JJG757‑2018 *Laboratory Ion Meter*, fulfilling all technical specifications for standard ion‑meter verification.
5. Adopting multi‑parameter architecture, it consolidates five measurement modes: pH, ISE ion concentration, mV potential, ORP and temperature detection.
6. Three sets of built‑in pH buffer standards are available: Chinese standard, European‑American standard and NIST standard.
7. The ISE ion‑concentration mode pre‑loads 10 frequently‑measured ions, with capacity for 3 user‑defined ions. Four measurement units are selectable: pX, mol/L, mg/L and ppm.
8. It supports calibration routines, auto/manual temperature compensation, as well as automatic and manual data‑saving options.
9. Three acquisition modes are provided: real‑time measurement, interval‑based measurement and scheduled timed measurement.
10. Up to 5000 data records can be saved for each test parameter. Records can be retrieved, deleted and printed, and data remains intact upon power loss.
11. Built‑in Bluetooth enables printing and data transmission. Both real‑time readings and historical datasets can be printed or transferred externally.
12. Standard accessories include a laboratory electromagnetic stirrer and electrode holder, securing stable conditions and reliable accuracy during lab tests.

Technical parameter

Detection parameters

1.PH

1.1 Measurement range: (0~14) pH

1.2 Response time: ≤ 30 seconds

1.3 Measurement accuracy: ± 0.02pH

1.4 Resolution: 0.01pH

1.5 Temperature compensation: (5-60) ℃ automatic

1.6 Calibration method: 1-5 point calibration

2.ORP

2.1 Measurement range: -1000mV~1000mV

2.2 Response time: ≤ 30 seconds

2.3 Measurement accuracy: ± 1mV

2.4 Resolution: 0.01

2.5 Temperature compensation: (5-60) ℃ automatic

2.6 Calibration method: 1-point calibration

3. Temperature

3.1 Measurement range: (0~100) ℃

3.2 Response time: ≤ 30 seconds

3.3 Measurement accuracy: 1%

3.4 Resolution: 0.01 ℃

3.5 Calibration method: 1-point calibration

4. Fluoride ion

4.1 Measurement range: (0.019-1900) mg/L

4.2 Response time: ≤ 60 seconds

4.3 Measurement accuracy: ± 10%

4.4 Resolution: 0.1mV

4.5 Temperature compensation: (5-60) ℃ automatic

4.6 Calibration method: 2-point calibration

5. Chloride ion

5.1 Measurement range: (0.7-3500) mg/L

5.2 Response time: ≤ 60 seconds

5.3 Measurement accuracy: ± 10%

5.4 Resolution: 0.1mV

5.5 Temperature compensation: (5-60) ℃ automatic

5.6 Calibration method: 2-point calibration

6. Bromine ion

6.1 Measurement range: (0.4-8000) mg/L

6.2 Response time: ≤ 60 seconds

6.3 Measurement accuracy: ± 10%

6.4 Resolution: 0.1mV

6.5 Temperature compensation: (5-60) ℃ automatic

6.6 Calibration method: 2-point calibration

7. Iodine ion

7.1 Measurement range: (0.1-12700) mg/L

7.2 Response time: ≤ 60 seconds

7.3 Measurement accuracy: ± 10%

7.4 Resolution: 0.1mV

7.5 Temperature compensation: (5-60) ℃ automatic

7.6 Calibration method: 2-point calibration

8. Calcium ion

8.1 Measurement range: (0.4-4000) mg/L

8.2 Response time: ≤ 60 seconds

8.3 Measurement accuracy: ± 10%

8.4 Resolution: 0.1mV

8.5 Temperature compensation: (5-60) ℃ automatic

8.6 Calibration method: 2-point calibration

9. Nitrate ion

9.1 Measurement range: (0.62-6200) mg/L

9.2 Response time: ≤ 60 seconds

9.3 Measurement accuracy: ± 10%

9.4 Resolution: 0.1mV

9.5 Temperature compensation: (5-60) ℃ automatic

9.6 Calibration method: 2-point calibration

10. Ammonium ion

10.1 Measurement range: (0.018-1800) mg/L

10.2 Response time: ≤ 60 seconds

10.3 Measurement accuracy: ± 10%

10.4 Resolution: 0.1mV

10.5 Temperature compensation: (5-60) ℃ automatic

10.6 Calibration method: 2-point calibration

11. Potassium ion

11.1 Measurement range: (0.39-3900) mg/L

11.2 Response time: ≤ 60 seconds

11.3 Measurement accuracy: ± 10%

11.4 Resolution: 0.1mV

11.5 Temperature compensation: (5-60) ℃ automatic

11.6 Calibration method: 2-point calibration

12. Sodium ion

12.1 Measurement range: (0.23-2300) mg/L

12.2 Response time: ≤ 60 seconds

12.3 Measurement accuracy: ± 10%

12.4 Resolution: 0.1mV

12.5 Temperature compensation: (5-60) ℃ automatic

12.6 Calibration method: 2-point calibration

13. Copper ion

13.1 Measurement range: (0.64-6400) mg/L

13.2 Response time: ≤ 60 seconds

13.3 Measurement accuracy: ± 10%

13.4 Resolution: 0.1mV

13.5 Temperature compensation: (5-60) ℃ automatic

13.6 Calibration method: 2-point calibration

Performance parameter

4.1 Measurement range: pH/pX: (0.000~20.000) pH; 0.000~14.000pX

mV:(-2000.00~2000.00mV

Ionic concentration: (0-1) mol/L; Optional units: pX, mol/L, mg/L, ppm;

Resolution: pH/pX: 0.001, 0.01, 0.1pH/pX; optional

MV: 0.01, 0.1, 1mV optional

Temperature: 0.1 ℃;

4.3 Basic Error: Complies with the 0.01 level requirements of JJG757-2018 Laboratory Ion Meter

Error of pX Ⅰ reading of the electric meter: ± 0.01; PX Ⅱ indication error: ± 0.02

Potential indication error: ± 0.1% F.S;

Temperature: ± 0.5 ℃;

5. Physical parameters

5.1 Display screen: 7-inch touch LCD display screen;

5.2 Printer: Optional portable Bluetooth printer;

5.3 Communication method: USB transmission;

5.4 Instrument size: 226 * 158 * 62mm

5.5 Whole machine weight: 1.1Kg.

6. Working parameters

6.1 Operating temperature: (0~60) ℃;

6.2 Working power supply: DC12V, 1A;

6.3 Host power: 6W

Instrument name

Ion meter

Instrument model

LH-E4ISE

Measurement metrics

Measurement range

Measurement accuracy

Resolution

Response time

Temperature compensation

Calibration method

pH

0-14

±0.02

0.01

≤30s

(5-60℃(automatic)

1-5 points

ORP

-1000-+1000mV

±1mV

0.01mV

≤30s

(5-60)℃(automatic)

1 point

Temperature

0-100℃

1%

0.01℃

≤30s

/

1 point

Fluoride ion

0.019-1900

±10%

0.1mV

≤60s

(5-60)℃(manual)

2 points

Chloride ion

0.7-3500

±10%

0.1mV

≤60s

(5-60)℃(manual)

2 points

Bromide ion

0.4-8000

±10%

0.1mV

≤60s

(5-60)℃(manual)

2 points

Iodide ion

0.1-12700

±10%

0.1mV

≤60s

(5-60)℃(manual)

2 points

Calcium ion

0.4-4000

±10%

0.1mV

≤60s

(5-60)℃(manual)

2 points

Nitrate

0.62-6200

±10%

0.1mV

≤60s

(5-60)℃(manual)

2 points

Ammonium ion

0.018-1800

±10%

0.1mV

≤60s

(5-60)℃(manual)

2 points

Potassium ion

0.39-3900

±10%

0.1mV

≤60s

(5-60)℃(manual)

2 points

Sodium ion

0.023-2300

±10%

0.1mV

≤60s

(5-60)℃(manual)

2 points

Copper ion

0.64-6400

±10%

0.1mV

≤60s

(5-60)℃(manual)

2 points

Have something in mind? Let's talk.

Adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim.

Contact Us

Name
Email
Mobile
WhatsApp
Company Name
Message
0/1000

Contact Us

Name
Email
Mobile
WhatsApp
Company Name
Message
0/1000

Related Search

ion meter lh e4ise-0